AdapterId 0FF6Fh AdapterName "Built In Features" NumBytes 4 FixedResources pos[0]=XXXXXX11b pos[27]=XXXXXXX1b pos[28]=0XXXXX00b pos[29]=11111101b pos[30]=1100XXXXb io 03f0h-03f7h int 6 arb 2 mem 0fc000000h - 0fdffffffh 0fffe0000h - 0ffffffffh exec sysmem 1024 32 address 32 Begin NamedItem Prompt "Serial Port" choice "SERIAL 1" pos[0]=XXXX11XXb pos[3]=X000XXXXb io 03f8h-03ffh 083f8h-083ffh int 4 choice "SERIAL 2" pos[0]=XXXX01XXb pos[3]=X001XXXXb io 02f8h-02ffh 082f8h-082ffh int 3 choice "SERIAL 3" pos[0]=XXXX01XXb pos[3]=X010XXXXb io 3220h-3227h 0b220h-0b227h int 3 choice "SERIAL 4" pos[0]=XXXX01XXb pos[3]=X011XXXXb io 3228h-322fh 0b228h-0b22fh int 3 choice "SERIAL 5" pos[0]=XXXX01XXb pos[3]=X100XXXXb io 4220h-4227h 0c220h-0c227h int 3 choice "SERIAL 6" pos[0]=XXXX01XXb pos[3]=X101XXXXb io 4228h-422fh 0c228h-0c22fh int 3 choice "SERIAL 7" pos[0]=XXXX01XXb pos[3]=X110XXXXb io 5220h-5227h 0d220h-0d227h int 3 choice "SERIAL 8" pos[0]=XXXX01XXb pos[3]=X111XXXXb io 5228h-522fh 0d228h-0d22fh int 3 choice "Disabled" pos[0]=XXXXX0XXb Help "The built-in serial port connector can be assigned as Serial 1 through Serial 8, or disabled. Use the F5=Previous and the F6=Next keys to change serial port assignments if you are in the 'Change configuration' window. Conflicting assignments are marked with an asterisk and should be changed." NamedItem Prompt "Serial Transmit Arbitration Level" choice "Shared 7" pos[2]=XXXX0111b pos[1]=1XXXXXXXb arb SharedArb 7 choice "Shared 6" pos[2]=XXXX0110b pos[1]=1XXXXXXXb arb SharedArb 6 choice "Shared 5" pos[2]=XXXX0101b pos[1]=1XXXXXXXb arb SharedArb 5 choice "Shared 4" pos[2]=XXXX0100b pos[1]=1XXXXXXXb arb SharedArb 4 choice "Shared 3" pos[2]=XXXX0011b pos[1]=1XXXXXXXb arb SharedArb 3 choice "Shared 1" pos[2]=XXXX0001b pos[1]=1XXXXXXXb arb SharedArb 1 choice "Shared 0" pos[2]=XXXX0000b pos[1]=1XXXXXXXb arb SharedArb 0 choice "Dedicated 7" pos[2]=XXXX0111b pos[1]=0XXXXXXXb arb 7 choice "Dedicated 6" pos[2]=XXXX0110b pos[1]=0XXXXXXXb arb 6 choice "Dedicated 5" pos[2]=XXXX0101b pos[1]=0XXXXXXXb arb 5 choice "Dedicated 4" pos[2]=XXXX0100b pos[1]=0XXXXXXXb arb 4 choice "Dedicated 3" pos[2]=XXXX0011b pos[1]=0XXXXXXXb arb 3 choice "Dedicated 1" pos[2]=XXXX0001b pos[1]=0XXXXXXXb arb 1 choice "Dedicated 0" pos[2]=XXXX0000b pos[1]=0XXXXXXXb arb 0 choice "Disabled" pos[2]=XXXX1111b Help "The built-in serial port connector can be assigned any one of the available arbitration levels for transmitting data. Selecting a shared level allows other devices with shared levels to use the same value. Selecting a dedicated level allows only this device to use the value. Use the F5=Previous and the F6=Next keys to change arbitration level assignments if you are in the 'Change configuration' window. Conflicting assignments are marked with an asterisk and should be changed." NamedItem Prompt "Serial Receive Arbitration Level" choice "Shared 7" pos[2]=0111XXXXb pos[1]=X1XXXXXXb arb SharedArb 7 choice "Shared 6" pos[2]=0110XXXXb pos[1]=X1XXXXXXb arb SharedArb 6 choice "Shared 5" pos[2]=0101XXXXb pos[1]=X1XXXXXXb arb SharedArb 5 choice "Shared 4" pos[2]=0100XXXXb pos[1]=X1XXXXXXb arb SharedArb 4 choice "Shared 3" pos[2]=0011XXXXb pos[1]=X1XXXXXXb arb SharedArb 3 choice "Shared 1" pos[2]=0001XXXXb pos[1]=X1XXXXXXb arb SharedArb 1 choice "Shared 0" pos[2]=0000XXXXb pos[1]=X1XXXXXXb arb SharedArb 0 choice "Dedicated 7" pos[2]=0111XXXXb pos[1]=X0XXXXXXb arb 7 choice "Dedicated 6" pos[2]=0110XXXXb pos[1]=X0XXXXXXb arb 6 choice "Dedicated 5" pos[2]=0101XXXXb pos[1]=X0XXXXXXb arb 5 choice "Dedicated 4" pos[2]=0100XXXXb pos[1]=X0XXXXXXb arb 4 choice "Dedicated 3" pos[2]=0011XXXXb pos[1]=X0XXXXXXb arb 3 choice "Dedicated 1" pos[2]=0001XXXXb pos[1]=X0XXXXXXb arb 1 choice "Dedicated 0" pos[2]=0000XXXXb pos[1]=X0XXXXXXb arb 0 choice "Disabled" pos[2]=1111XXXXb Help "The built-in serial port connector can be assigned any one of the available arbitration levels for receiving data. Selecting a shared level allows other devices with shared levels use the same value. Selecting a dedicated level allows only this device to use the value. Use the F5=Previous and the F6=Next keys to change arbitration level assignments if you are in the 'Change configuration' window. Conflicting assignments are marked with an asterisk and should be changed." End Begin NamedItem Prompt "Parallel Port" choice "PARALLEL 1" pos[0]=X001XXXXb io 03bch-03bfh 1278h-127fh int 7 choice "PARALLEL 2" pos[0]=X011XXXXb io 0378h-037fh int 7 choice "PARALLEL 3" pos[0]=X101XXXXb io 0278h-027fh int 7 choice "Disabled" pos[0]=X000XXXXb Help "The built-in parallel port connector can be assigned as Parallel 1 through Parallel 3 or disabled. Use the F5=Previous and the F6=Next keys to change parallel port assignments if you are in the 'Change configuration' window. Conflicting assignments are marked with an asterisk and should be changed." NamedItem Prompt "Parallel Port Arbitration Level" choice "Shared 7" pos[3]=XXXX0111b pos[1]=XX1XXXXXb pos[0]=0XXXXXXXb arb SharedArb 7 choice "Shared 6" pos[3]=XXXX0110b pos[1]=XX1XXXXXb pos[0]=0XXXXXXXb arb SharedArb 6 choice "Shared 5" pos[3]=XXXX0101b pos[1]=XX1XXXXXb pos[0]=0XXXXXXXb arb SharedArb 5 choice "Shared 4" pos[3]=XXXX0100b pos[1]=XX1XXXXXb pos[0]=0XXXXXXXb arb SharedArb 4 choice "Shared 3" pos[3]=XXXX0011b pos[1]=XX1XXXXXb pos[0]=0XXXXXXXb arb SharedArb 3 choice "Shared 1" pos[3]=XXXX0001b pos[1]=XX1XXXXXb pos[0]=0XXXXXXXb arb SharedArb 1 choice "Shared 0" pos[3]=XXXX0000b pos[1]=XX1XXXXXb pos[0]=0XXXXXXXb arb SharedArb 0 choice "Dedicated 7" pos[3]=XXXX0111b pos[1]=XX0XXXXXb pos[0]=0XXXXXXXb arb 7 choice "Dedicated 6" pos[3]=XXXX0110b pos[1]=XX0XXXXXb pos[0]=0XXXXXXXb arb 6 choice "Dedicated 5" pos[3]=XXXX0101b pos[1]=XX0XXXXXb pos[0]=0XXXXXXXb arb 5 choice "Dedicated 4" pos[3]=XXXX0100b pos[1]=XX0XXXXXb pos[0]=0XXXXXXXb arb 4 choice "Dedicated 3" pos[3]=XXXX0011b pos[1]=XX0XXXXXb pos[0]=0XXXXXXXb arb 3 choice "Dedicated 1" pos[3]=XXXX0001b pos[1]=XX0XXXXXb pos[0]=0XXXXXXXb arb 1 choice "Dedicated 0" pos[3]=XXXX0000b pos[1]=XX0XXXXXb pos[0]=0XXXXXXXb arb 0 choice "Disabled" pos[3]=XXXX1111b pos[0]=1XXXXXXXb Help "The built-in parallel port connector can be assigned any one of the available arbitration levels. Selecting a shared level allows other devices with shared levels to use the same value. Selecting a dedicated level allows only this device to use the value. Select to use the parallel port in compatibility mode. Use the F5=Previous and the F6=Next keys to change arbitration level assignments if you are in the 'Change configuration' window. Conflicting assignments are marked with an asterisk and should be changed." End NamedItem Prompt "Preempt Enable/Disable" Choice "Enable" pos[31]=X0XXXXXXb Choice "Disable" pos[31]=X1XXXXXXb Help "System Board Processor Preempt. This function allows the system board processor to preempt continuous data transfers by other devices for its use of the Micro Channel. Under normal circumstances, select ." Begin Device 3 2 0 NoDMA NamedItem Prompt "Video I/O Address" choice "Instance 6: 2160h - 216Fh" pos[27]=XXXX110Xb io 02160h-0216fh choice "Instance 1: 2110h - 211Fh" pos[27]=XXXX001Xb io 02110h-0211fh choice "Instance 2: 2120h - 212Fh" pos[27]=XXXX010Xb io 02120h-0212fh choice "Instance 3: 2130h - 213Fh" pos[27]=XXXX011Xb io 02130h-0213fh choice "Instance 4: 2140h - 214Fh" pos[27]=XXXX100Xb io 02140h-0214fh choice "Instance 5: 2150h - 215Fh" pos[27]=XXXX101Xb io 02150h-0215fh Help "The Video I/O address selects a particular I/O address range for the Display Controller Registers. This field also affects the exact location of the video coprocessor registers." NamedItem Prompt "Video ROM Address Space" choice "C0000 - C1FFF" pos[27]=0000XXXXb mem 0c0000h-0c1fffh choice "C2000 - C3FFF" pos[27]=0001XXXXb mem 0c2000h-0c3fffh choice "C4000 - C5FFF" pos[27]=0010XXXXb mem 0c4000h-0c5fffh choice "C6000 - C7FFF" pos[27]=0011XXXXb mem 0c6000h-0c7fffh choice "C8000 - C9FFF" pos[27]=0100XXXXb mem 0c8000h-0c9fffh choice "CA000 - CBFFF" pos[27]=0101XXXXb mem 0ca000h-0cbfffh choice "CC000 - CDFFF" pos[27]=0110XXXXb mem 0cc000h-0cdfffh choice "CE000 - CFFFF" pos[27]=0111XXXXb mem 0ce000h-0cffffh choice "D0000 - D1FFF" pos[27]=1000XXXXb mem 0d0000h-0d1fffh choice "D2000 - D3FFF" pos[27]=1001XXXXb mem 0d2000h-0d3fffh choice "D4000 - D5FFF" pos[27]=1010XXXXb mem 0d4000h-0d5fffh choice "D6000 - D7FFF" pos[27]=1011XXXXb mem 0d6000h-0d7fffh choice "D8000 - D9FFF" pos[27]=1100XXXXb mem 0d8000h-0d9fffh choice "DA000 - DBFFF" pos[27]=1101XXXXb mem 0da000h-0dbfffh choice "DC000 - DDFFF" pos[27]=1110XXXXb mem 0dc000h-0ddfffh choice "DE000 - DFFFF" pos[27]=1111XXXXb mem 0de000h-0dffffh Help "The Video ROM Address Space item defines the memory address range used for the system video ROM. If you are in the Change Configuration window, you can use the F5=Previous and F6=Next keys to select a non-conflicting ROM address range for the system video. Conflicting assignments are marked with an asterisk and should be changed." NamedItem Prompt "Video Arbitration Level" choice "Arbitration level 13" pos[28]=X1101XXXb arb 0dh choice "Arbitration level 12" pos[28]=X1100XXXb arb 0ch choice "Arbitration level 11" pos[28]=X1011XXXb arb 0bh choice "Arbitration level 10" pos[28]=X1010XXXb arb 0ah choice "Arbitration level 9" pos[28]=X1001XXXb arb 9 choice "Arbitration level 8" pos[28]=X1000XXXb arb 8 choice "Arbitration level 14" pos[28]=X1110XXXb arb 0eh Help "The video sub-system can be assigned any one of the available arbitration levels 8 through 14. Use the F5=Previous and the F6=Next keys to change arbitration level assignments if you are in the 'Change configuration' window. Conflicting assignments are marked with an asterisk and should be changed." NamedItem Prompt "Video Fairness" choice "Fairness On" pos[28]=XXXXX1XXb choice "Fairness Off" pos[28]=XXXXX0XXb Help "Video Fairness indicates whether or not the video sub-system coprocessor will follow the fairness algorithm for bus usage. This setting can be changed if you are in the 'Change Configuration' window by using the F5=Previous and F6=Next keys." End