AdapterId 07052h AdapterName "AST RampagePlus/MC With I/O Pak/MC-SP Option" NumBytes 4 NamedItem Prompt "Wait State" choice "1 wait state " pos[1]=0XXXXXXXb choice "0 wait state " pos[1]=1XXXXXXXb Help "Memory WAIT STATE selection" NamedItem Prompt "Memory Configuration" choice "DISABLED" pos[0]=1010000Xb choice ".5M,0K,0K,0K TOTAL = 0.5 MB" pos[0]=1111001Xb choice ".5M,.5M,0K,0K TOTAL = 1.0 MB" pos[0]=1110001Xb choice ".5M,.5M,.5M,0K TOTAL = 1.5 MB" pos[0]=1101001Xb choice ".5M,.5M,.5M,.5M TOTAL = 2.0 MB" pos[0]=1100001Xb choice " 2M,0K,0K,0K TOTAL = 2.0 MB" pos[0]=1001001Xb choice ".5M,2M,0K,0K TOTAL = 2.5 MB" pos[0]=0110001Xb choice ".5M,.5M,2M,0K TOTAL = 3.0 MB" pos[0]=0101001Xb choice ".5M,.5M,.5M,2M TOTAL = 3.5 MB" pos[0]=0100001Xb choice " 2M,2M,0K,0K TOTAL = 4.0 MB" pos[0]=1000001Xb choice ".5M,2M,2M,0K TOTAL = 4.5 MB" pos[0]=0011001Xb choice ".5M,.5M,2M,2M TOTAL = 5.0 MB" pos[0]=0111001Xb choice " 2M,2M,2M,0K TOTAL = 6.0 MB" pos[0]=0001001Xb choice ".5M,2M,2M,2M TOTAL = 6.5 MB" pos[0]=0010001Xb choice " 2M,2M,2M,2M TOTAL = 8.0 MB" pos[0]=0000001Xb Help "This is memory configuration on your RampagePlus/MC starting from top of the board BANK0,BANK1,BANK2,BANK3" NamedItem Prompt "Connector 1" choice "SERIAL_1" pos[2]=xxxx0001b io 03f8h-03ffh int 4 choice "SERIAL_2" pos[2]=xxxx0011b io 02f8h-02ffh int 3 choice "SERIAL_3" pos[2]=xxxx0101b io 3220h-3227h int 3 choice "SERIAL_4" pos[2]=xxxx0111b io 3228h-322fh int 3 choice "SERIAL_5" pos[2]=xxxx1001b io 4220h-4227h int 3 choice "SERIAL_6" pos[2]=xxxx1011b io 4228h-422fh int 3 choice "SERIAL_7" pos[2]=xxxx1101b io 5220h-5227h int 3 choice "SERIAL_8" pos[2]=xxxx1111b io 5228h-522fh int 3 choice "DISABLE" pos[2]=xxxxxxx0b Help "Connector 1 of RampagePlus/MC Serial and Parallel Port Option can have any one of the Serial 1 to Serial 8 assignments and can also be disabled. Use the F5= Previous and the F6=Next keys to change the Connector 1 Serial port assignments when you are in the 'Change Configuration' window. Conflicting assignments are marked with an Asterisk and should be changed." NamedItem Prompt "Connector 2" choice "PARALLEL_1" pos[2]=xx01xxxxb io 03bch-03bfh int 7 choice "PARALLEL_2" pos[2]=xx10xxxxb io 0378h-037fh int 7 choice "PARALLEL_3" pos[2]=xx11xxxxb io 0278h-027fh int 5 choice "DISABLE" pos[2]=xx00xxxxb Help "Connector 2 of the RampagePlus/MC Serial and Parallel Port Option can have any one of the Parallel 1 to Parallel 3 assignments and can also be disabled. Use the F5=Previous and the F6=Next keys to change the Connector 2 Parallel Port assignments when you are in the 'Change Configuration' window. Conflicting assig- nments are marked with an Asterisk and should be changed."